Diagnosis · Pre-gelation — free calcium

Free calcium is triggering the gel in the tank

Low acyl gellan responds to free divalent cations almost immediately on cooling. If the calcium is available while the batch is still being held, the network starts forming in the tank.

Start the diagnosis again

What to do

  1. Add a sequestrant: sodium citrate 0.05–0.15%, or sodium hexametaphosphate, to hold the calcium until the temperature drops.
  2. Add the gellan last, after the salts, so it never meets a high local calcium concentration.
  3. Dry blend the gellan with the sequestrant itself for a slower, more uniform release.
  4. If the recipe cannot take a citrate, high acyl gellan is far less ion sensitive — at the cost of a softer gel.

The reading behind this

How this conclusion was reached
  1. What is actually going wrong?

    It sets before I can fill it

  2. Is the batch setting inside the tank, or on the way down a long fill line?

    In the tank, before filling starts

  3. Is the formula high in calcium or magnesium?

    Yes, there is a clear divalent source

Check this against your own system

This describes the usual cause. What actually fixes it depends on your water hardness, total solids and fill temperature — send those three numbers and we will come back with a starting point, or with a bench sample of the grade this points to.